UNILAB Retro Basic PSU

UNILAB Retro Basic PSU

E1009597

Product code: E1009597

-
+

The entry level power supply in the Unilab Retro range. The Lockable Power Unit provides a.c. or d.c. at 2, 4, 6, 9 or 12 volts, at up to 4 amps. This unit is well suited to everyday power requirements, such as basic electricity, ray optics boxes and immersion heaters. The voltage is selected using a five-position switch, and can be locked either at a particular voltage, or within a range of voltages, by way of hex socket screws surrounding the selector switch. An Allen key is provided for the teacher or technician to set the desired locks.

The form of the output is set by a separate switch, either a.c. or unsmoothed, unregulated d.c. Two shrouded 4mm sockets provide the output, and the shroud can be partially unscrewed for other types of connection, such as bare wires. a.c. and d.c. are output from the same sockets, and never simultaneously, preventing students from connecting the a.c. and d.c. outputs together.

The unit has two in-built layers of protection. The first is a thermal trip on the secondary circuit, with a reset button for when the problem load has been disconnected. The second is a 1A mains fuse, accessed from the front panel, on the primary circuit.

  • Locking mechanism to limit or pre-set the voltage available to students in specific experiments (a standard 3mm Allen/Hex Key is appropriate for locking the voltage if the original is misplaced).
  • 4mm output socket/terminals.
  • Thermal "trip", which can be reset shortly after removal of the excess load.
  • Robustly made with captive mains lead and integral cable wraps on the back panel.
  • Protected by a time delay mains fuse in the front panel.

Complies to EN61010 2010, certificate available on request.

  • Dimensions: (L)290mm x (W)165mm x (H)165mm.
  • Robust
  • Rotary Voltage Selection
  • Maximum Current: 4A
  • Applications throughout Key Stage 3, GCSE and A-Level
  • Spare parts available: Red and black terminal sockets, bracket cable wrap, fuse holder
  • For availability of other spares, please contact techsupport@philipharris.co.uk

Further Information

Age Recommended from
11 Years
Brand
Unilab
Fuse (front panel)
T1A (time delay)
Humidity Limits (%RH)
10 - 90
Mains input
230V ac 50Hz
Max current (A)
4
Maximum Voltage
12V
Offers
Buy More Save More
Output Control
Stepped
Output range (V)
2
4
6
9
12 ac or dc unsmoothed
Power rating (VA)
80
Power Supply Type
Retro Basic
Product Type
Power Supply Units
Temperature Limits (°C)
-5 to 50

Documents

-
+

The entry level power supply in the Unilab Retro range. The Lockable Power Unit provides a.c. or d.c. at 2, 4, 6, 9 or 12 volts, at up to 4 amps. This unit is well suited to everyday power requirements, such as basic electricity, ray optics boxes and immersion heaters. The voltage is selected using a five-position switch, and can be locked either at a particular voltage, or within a range of voltages, by way of hex socket screws surrounding the selector switch. An Allen key is provided for the teacher or technician to set the desired locks.

The form of the output is set by a separate switch, either a.c. or unsmoothed, unregulated d.c. Two shrouded 4mm sockets provide the output, and the shroud can be partially unscrewed for other types of connection, such as bare wires. a.c. and d.c. are output from the same sockets, and never simultaneously, preventing students from connecting the a.c. and d.c. outputs together.

The unit has two in-built layers of protection. The first is a thermal trip on the secondary circuit, with a reset button for when the problem load has been disconnected. The second is a 1A mains fuse, accessed from the front panel, on the primary circuit.

  • Locking mechanism to limit or pre-set the voltage available to students in specific experiments (a standard 3mm Allen/Hex Key is appropriate for locking the voltage if the original is misplaced).
  • 4mm output socket/terminals.
  • Thermal "trip", which can be reset shortly after removal of the excess load.
  • Robustly made with captive mains lead and integral cable wraps on the back panel.
  • Protected by a time delay mains fuse in the front panel.

Complies to EN61010 2010, certificate available on request.

  • Dimensions: (L)290mm x (W)165mm x (H)165mm.
  • Robust
  • Rotary Voltage Selection
  • Maximum Current: 4A
  • Applications throughout Key Stage 3, GCSE and A-Level
  • Spare parts available: Red and black terminal sockets, bracket cable wrap, fuse holder
  • For availability of other spares, please contact techsupport@philipharris.co.uk

Further Information

Age Recommended from
11 Years
Brand
Unilab
Fuse (front panel)
T1A (time delay)
Humidity Limits (%RH)
10 - 90
Mains input
230V ac 50Hz
Max current (A)
4
Maximum Voltage
12V
Offers
Buy More Save More
Output Control
Stepped
Output range (V)
2
4
6
9
12 ac or dc unsmoothed
Power rating (VA)
80
Power Supply Type
Retro Basic
Product Type
Power Supply Units
Temperature Limits (°C)
-5 to 50

Documents

You May Also Like

Shopping from Overseas?

We have detected that your IP address is not UK based.

We have a specific international website which deals with all non-UK transactions and deliveries. Please select which website you would like to continue with.

For International Delivery

Findel Education family logos Switch to Findel International

For Delivery in the UK

Brand logo