Philip Harris S-Range Digicounter

Philip Harris S-Range Digicounter

E1008422

Product code: E1008422

-
+

A versatile Digicounter suitable for timing, frequency, period and radioactivity measurement. A built-in high stability crystal controlled oscillator ensures a typical accuracy of 0.005% on all measuring ranges. The period measurement and display function enables very low frequencies to be measured rapidly with a high degree of accuracy. It also allows triggered timing of trolley speeds (etc.) to be performed using a single light gate; and by shorting the period input, infinite radioactivity or frequency counts may be obtained.

  • Full Notes for Use included.

Radioactivity:

  • Inputs: E.H.T BNC connector for a G.M. tube. Supply voltage adjustable from 300 to 500V
  • Counting time: 1, 10, 100 or 1000 seconds and infinity. Can be set to take a single or a continuous series of readings, each being displayed for 3 seconds before the next is taken
  • Rate: Obtained by dividing the count reading by the counting time
  • Speaker: Output will feed into a speaker of any impedance
  • Timing Ranges: 0 to 99.9999 x 0.1ms; 0 to 999.999 x 1ms; 0 to 9999.99 x 0.01s (10ms); 0 to 99999.9 x 0.1s (100ms)
  • Accuracy: Better than 0.005% ±1 count
  • Gating: (1) By manual front panel stop/start switch;(2) By make or break input sockets; (3) By triggering timing stop/start inputs. Output 2V and 6V a.c. at 0.5A for light gate or similar amps

Frequency Inputs:

  1. Low frequency, d.c. to 3MHz minimum (5MHz typical). Will operate with T.T.L inputs, light gates etc.
  2. High frequency, capacitively coupled 30Hz to 3MHz minimum (5MHz typical);
  3. High gain, input voltage required 0.8mV r.m.s. from 30Hz to 20kHz; recommended microphone - high impedance dynamic type
  • Input impedance: 20O for inputs (1) and (2); 100kO for input (3)
  • Accuracy: Better than 0.005% -+ 1 count

Period:

  • Timing intervals: 0.1, 1, 10 and 100ms

This device is compliant to EN61010-2010 with certificates available on request.

Related products include:

  • Geiger-Muller Tube (B8H27155) & Geiger-Muller Tube Holder (B8A49724)
  • Radioactive Source Handling Tool (B8A49608)
  • Radioactive Sources (B849589, B8A49578, or B8A49591)
  • Light Gate (B8H27623)
  • Atomic Physics & Radiation
  • Radioactivity

Further Information

Accuracy
Better than 0.005% ±1 count
Brand
Philip Harris
Curriculum Link
Atomic Physics & Radioactivity
Frequency Input Impedance
20O for inputs (1) and (2); 100kO for input (3)
Frequency Inputs
Low Frequency
High Frequency and High Gain
Geiger Muller Tube Input
E.H.T BNC connector
Supply voltage adjustable from 300 to 500V
Key Stage Suitability
Key Stage 4+
Period Timing Intervals
0.1
1
10 and 100ms
Product Type
Digicounter
Radioactivity Counting Time
1
10
100 or 1000 seconds and infinity
Radioactivity Timing Ranges
0 to 99.9999 x 0.1ms; 0 to 999.999 x 1ms; 0 to 9999.99 x 0.01s (10ms); 0 to 99999.9 x 0.1s (100ms)

Documents

-
+

A versatile Digicounter suitable for timing, frequency, period and radioactivity measurement. A built-in high stability crystal controlled oscillator ensures a typical accuracy of 0.005% on all measuring ranges. The period measurement and display function enables very low frequencies to be measured rapidly with a high degree of accuracy. It also allows triggered timing of trolley speeds (etc.) to be performed using a single light gate; and by shorting the period input, infinite radioactivity or frequency counts may be obtained.

  • Full Notes for Use included.

Radioactivity:

  • Inputs: E.H.T BNC connector for a G.M. tube. Supply voltage adjustable from 300 to 500V
  • Counting time: 1, 10, 100 or 1000 seconds and infinity. Can be set to take a single or a continuous series of readings, each being displayed for 3 seconds before the next is taken
  • Rate: Obtained by dividing the count reading by the counting time
  • Speaker: Output will feed into a speaker of any impedance
  • Timing Ranges: 0 to 99.9999 x 0.1ms; 0 to 999.999 x 1ms; 0 to 9999.99 x 0.01s (10ms); 0 to 99999.9 x 0.1s (100ms)
  • Accuracy: Better than 0.005% ±1 count
  • Gating: (1) By manual front panel stop/start switch;(2) By make or break input sockets; (3) By triggering timing stop/start inputs. Output 2V and 6V a.c. at 0.5A for light gate or similar amps

Frequency Inputs:

  1. Low frequency, d.c. to 3MHz minimum (5MHz typical). Will operate with T.T.L inputs, light gates etc.
  2. High frequency, capacitively coupled 30Hz to 3MHz minimum (5MHz typical);
  3. High gain, input voltage required 0.8mV r.m.s. from 30Hz to 20kHz; recommended microphone - high impedance dynamic type
  • Input impedance: 20O for inputs (1) and (2); 100kO for input (3)
  • Accuracy: Better than 0.005% -+ 1 count

Period:

  • Timing intervals: 0.1, 1, 10 and 100ms

This device is compliant to EN61010-2010 with certificates available on request.

Related products include:

  • Geiger-Muller Tube (B8H27155) & Geiger-Muller Tube Holder (B8A49724)
  • Radioactive Source Handling Tool (B8A49608)
  • Radioactive Sources (B849589, B8A49578, or B8A49591)
  • Light Gate (B8H27623)
  • Atomic Physics & Radiation
  • Radioactivity

Further Information

Accuracy
Better than 0.005% ±1 count
Brand
Philip Harris
Curriculum Link
Atomic Physics & Radioactivity
Frequency Input Impedance
20O for inputs (1) and (2); 100kO for input (3)
Frequency Inputs
Low Frequency
High Frequency and High Gain
Geiger Muller Tube Input
E.H.T BNC connector
Supply voltage adjustable from 300 to 500V
Key Stage Suitability
Key Stage 4+
Period Timing Intervals
0.1
1
10 and 100ms
Product Type
Digicounter
Radioactivity Counting Time
1
10
100 or 1000 seconds and infinity
Radioactivity Timing Ranges
0 to 99.9999 x 0.1ms; 0 to 999.999 x 1ms; 0 to 9999.99 x 0.01s (10ms); 0 to 99999.9 x 0.1s (100ms)