UNILAB Advanced Motion Measurement Kit KIT
UNILAB Advanced Motion Measurement Kit KIT
Product code: E1010340
Product Description
Our Advanced Motion Measurement Kit contains Light Gates and Motion QED which is a popular self-contained unit designed to store and calculate times, speeds and accelerations.
Based on our exclusive Unilab Motion QED unit, the Advanced Motion Measurement Kit contains one each of the following:
- Motion QED unit,
- Master Light Gate,
- Slave Light Gate.
- DIN Leads
Motion QED Specification:
- Event Timer: From 2 to 8 readings, timing each event.
- Interval Timing: From 1 to 4 readings: up to 4 successive obstructions on any combination of the four inputs can be measured and displayed.
- Speed: From 1 to 4 readings: speeds (in meters per second, display shows m/s) are calculated and displayed for mask lengths of 1 to 10cm (in 1cm steps) or from 10 to 200cm (in 10cm steps).
- Gap Timer: From 1 to 3 readings: similar to Interval Timing with only the leading edge of an obstruction being recognised so that times between gates are recorded and displayed.
- Average Speed: 1 reading: based on the Gap Timing Mode above, this program calculates and displays an average speed (in m/s) between gates which are from 10 to 200cm apart (in 10cm steps).
- Acceleration: 1 or 2 readings: for a vehicle carrying a single or double mask of known length passing through successive gates, the acceleration is calculated and displayed (as m/s/s).
Technical Details:
- Inputs: 4 TTL inputs protected against misconnection up to 20V a.c. or d.c.; 4mm sockets with 1 'Manual' push-button.
- Outputs: 12V to power external devices such as light gates; 4mm sockets
- Power: 12 to 16V a.c. or d.c. from a low voltage power supply.
- Protection: two internal 500mA anti-surge fuses.
- Timing: times to ±1ms.
- Mass: 0.9kg.
- Dimensions: 240mm x 135mm x 45mm
The Unilab Light Gate is fully protected against incorrect connection of signal or power and supplies from 9 to 25V a.c or d.c. can be used. A signal LED indicates that the Light Gate is functioning correctly when obstructed.
- Up to eight transitions of the light gates can be sensed and the times stored by the Motion QED unit.
All items included in the kit are also available to purchase separately.
- Key Stage 4 Physics - Forces and Motion, Acceleration, Speed: Make and interpret measurements of distances, times, speeds and accelerations,and represent these in graphical form. Explain the vector-scalar distinction as it applies to displacement, velocity and speed. Explain that motion in a circle involves constant speed but changing velocity (qualitative only).
Further Information
- Age Recommended from
- 11 Years
- Brand
- Unilab
- Fuse Information
- 2 x Internal 500mA anti-surge fuses
- Mass
- 0.9kg
- Motion Measurement
- Advanced Motion Measurement
- Outputs
- 12V to power external Light Gates
- Product Type
- Motion Measurement Kit
- QED Dimensions
- 240mm x 135mm x 45mm
- QED Inputs
- 4 x TTL
- Timing
- Times to ±1ms
Documents
Our Advanced Motion Measurement Kit contains Light Gates and Motion QED which is a popular self-contained unit designed to store and calculate times, speeds and accelerations.
Based on our exclusive Unilab Motion QED unit, the Advanced Motion Measurement Kit contains one each of the following:
- Motion QED unit,
- Master Light Gate,
- Slave Light Gate.
- DIN Leads
Motion QED Specification:
- Event Timer: From 2 to 8 readings, timing each event.
- Interval Timing: From 1 to 4 readings: up to 4 successive obstructions on any combination of the four inputs can be measured and displayed.
- Speed: From 1 to 4 readings: speeds (in meters per second, display shows m/s) are calculated and displayed for mask lengths of 1 to 10cm (in 1cm steps) or from 10 to 200cm (in 10cm steps).
- Gap Timer: From 1 to 3 readings: similar to Interval Timing with only the leading edge of an obstruction being recognised so that times between gates are recorded and displayed.
- Average Speed: 1 reading: based on the Gap Timing Mode above, this program calculates and displays an average speed (in m/s) between gates which are from 10 to 200cm apart (in 10cm steps).
- Acceleration: 1 or 2 readings: for a vehicle carrying a single or double mask of known length passing through successive gates, the acceleration is calculated and displayed (as m/s/s).
Technical Details:
- Inputs: 4 TTL inputs protected against misconnection up to 20V a.c. or d.c.; 4mm sockets with 1 'Manual' push-button.
- Outputs: 12V to power external devices such as light gates; 4mm sockets
- Power: 12 to 16V a.c. or d.c. from a low voltage power supply.
- Protection: two internal 500mA anti-surge fuses.
- Timing: times to ±1ms.
- Mass: 0.9kg.
- Dimensions: 240mm x 135mm x 45mm
The Unilab Light Gate is fully protected against incorrect connection of signal or power and supplies from 9 to 25V a.c or d.c. can be used. A signal LED indicates that the Light Gate is functioning correctly when obstructed.
- Up to eight transitions of the light gates can be sensed and the times stored by the Motion QED unit.
All items included in the kit are also available to purchase separately.
- Key Stage 4 Physics - Forces and Motion, Acceleration, Speed: Make and interpret measurements of distances, times, speeds and accelerations,and represent these in graphical form. Explain the vector-scalar distinction as it applies to displacement, velocity and speed. Explain that motion in a circle involves constant speed but changing velocity (qualitative only).
Further Information
- Age Recommended from
- 11 Years
- Brand
- Unilab
- Fuse Information
- 2 x Internal 500mA anti-surge fuses
- Mass
- 0.9kg
- Motion Measurement
- Advanced Motion Measurement
- Outputs
- 12V to power external Light Gates
- Product Type
- Motion Measurement Kit
- QED Dimensions
- 240mm x 135mm x 45mm
- QED Inputs
- 4 x TTL
- Timing
- Times to ±1ms